top of page
Australian industrial software & local integration
1800 560 854 info@prosightsoftware.com


HTTP Vary: Match the Report Representation Before Reusing Cached Data
The same report URL can return different representations. Inspect Vary and the original selecting request headers before reusing a cached response in an industrial integration.
10 hours ago3 min read


Content-Location and Location: Keep Report Identity Separate from Navigation
An integration can receive two URI-bearing headers with different meanings. Keep the identity of returned report content separate from a resource location or navigation decision.
14 hours ago3 min read


HTTP 501 During Integration: Confirm Server Functionality Before Changing the Payload
Distinguish HTTP 501 functionality failures from payload and temporary service errors, identify the responder and test supported integration operations.
3 days ago3 min read


HTTP 414 on a Report Query: Inspect the Final URI Before Removing Filters
Investigate HTTP 414 report requests by preserving the final encoded URI, checking filter construction and testing the documented query interface.
3 days ago3 min read


HTTP 411 on a Data Upload: Measure the Encoded Body, Not the Character Count
Diagnose HTTP 411 uploads, verify encoded byte length and request framing, and preserve the source batch before testing a corrected submission.
4 days ago3 min read


HTTP 416 on a Resumed Report Download: Verify the File Before Appending Bytes
Diagnose HTTP 416 during a report download, verify representation identity and length, and avoid appending a replacement file to an older partial copy.
4 days ago4 min read


HTTP 409 Conflict: Compare Resource State Before Repeating an Industrial API Update
Investigate HTTP 409 conflicts, compare the current resource with the proposed update and define a controlled recovery test for industrial integrations.
4 days ago3 min read


HTTP 408 During a Telemetry Upload: Separate Server Request Timeout from Client Timeout
Diagnose HTTP 408 in an industrial data upload, distinguish local timeouts and verify application evidence before retrying a batch.
5 days ago4 min read


HTTP 205 Reset Content: Clear the Entry View Without Losing Submission Evidence
A data-entry client receives HTTP 205 after submitting an industrial record. The next screen should not accidentally carry the previous entry forward, but clearing every trace of the submission is also unhelpful. Separate the entry-view reset from the application's evidence and acceptance workflow.
6 days ago3 min read


HTTP 422 on a Valid Upload: Check Meaning Before Reformatting the JSON
An industrial data upload parses as JSON but receives HTTP 422. Repeatedly reformatting whitespace may leave the actual problem untouched. Read the endpoint's validation response and compare the submitted meaning with the documented contract before changing values or resending the batch.
7 days ago3 min read


HTTP 410 Gone: Retire the Polling Route Without Deleting the Measurement History
A monitoring integration keeps polling an old endpoint and receives HTTP 410. Treat that as a resource-lifecycle question before increasing retries. Confirm the retired route, preserve the last verified readings and arrange a documented replacement rather than silently substituting another source.
7 days ago3 min read


HTTP 304 with No Body: Validate the Cached Record Before Importing
A periodic retrieval returns HTTP 304 and a JSON parser reports an empty response. Before changing the data source, inspect the conditional request and the locally retained representation. A validation response can be correct while the receiving workflow is using the wrong processing path.
Nov 153 min read


Report Download Filenames: Treat Content-Disposition as a Suggestion
An automated report download arrives with a filename that looks like a folder path, uses an unexpected extension or loses accented characters. Preserve the original response, but do not let its suggested name decide where the application writes a file. Separate file identity, display naming and storage policy.
Nov 143 min read


HTTP 201 Created: Record the Resource Before Retrying an Upload
An upload receives HTTP 201, but the client treats the unfamiliar response as a failure and sends the same creation request again. Before retrying, record the returned resource identity and verify the endpoint contract. A created record and a completed engineering workflow are different acceptance questions.
Nov 144 min read


HTTP 303 and 307: Check the Follow-Up Method Before Retrying an Upload
An industrial uploader receives a redirect after sending a test record. The follow-up request may be a retrieval of another resource or a repetition of the original method at a new location. Check the exact status and endpoint contract before treating every redirect as the same retry instruction.
Nov 143 min read


HTTP 206 Partial Content: Verify Completeness Before Importing a Dataset
An export download succeeds, but the imported report contains only the first part of its expected records. Check the HTTP status and response boundaries before investigating sensor storage. A 206 response can be a correct partial transfer rather than a complete file.
Nov 133 min read


HTTP 204 but JSON Parsing Fails? Handle No-Content Success Explicitly
Diagnose a JSON error after HTTP 204, separate no-content success from malformed data, and test the response-handling boundary before retrying industrial integration writes.
Nov 123 min read


CSV Notes Span Two Lines: Count Parsed Records Before Splitting a Handover File
An export contains 100 maintenance records, but a line-based check reports more rows and a file splitter creates broken fragments. A quoted note can contain its own line break. Parse the agreed CSV dialect before counting records, assigning error locations or dividing the file into batches.
Nov 114 min read


HTTP Telemetry Will Not Parse? Check Whether Gzip Was Already Decoded
An HTTP response declares gzip, but the integration’s decompression step reports that the body is not compressed. The HTTP client may already have decoded it. Establish what bytes each layer receives before changing the telemetry schema or adding another decoder.
Nov 104 min read


Sensor Arrays Change Order: Map Measurements by Identity, Not Position
Prevent changing array order from swapping measurements. Define channel identity, reject ambiguous records and verify a controlled synthetic test.
Nov 93 min read
bottom of page
.png)